97久久超碰国产视觉盛宴_一级黄片毛片久久_免费人成视频网站在线播放_国产黄色一区二区三区av_热久久精品手机观看_日韩一本高清中文字幕_日本无彩翼成人漫画全彩在线观看_国产最大黄色视频在线观看_制服丝袜中文字幕自拍有码_无码无卡高清免费视频a级

35KV及以下銅、鋁芯電力電纜

聚氯乙烯絕緣電力電纜
日期:08-20

  產(chǎn)品標(biāo)準(zhǔn)

  Standard

  本產(chǎn)品按GB12706《額定電壓35KV及以下銅芯、鋁芯塑料絕緣電力電纜》標(biāo)準(zhǔn)生產(chǎn),同時還可根據(jù)用戶需要按國際電工委員會推薦標(biāo)準(zhǔn)IEC、英國標(biāo)準(zhǔn)、德國標(biāo)準(zhǔn)及美國標(biāo)準(zhǔn)生產(chǎn)。

  The product is manufactured according to the standard of GB12706 or IEC , BS , DIN and ICEA upon request

  適合范圍

  Applications

  本產(chǎn)品適用于額定電壓35KV及以下配電網(wǎng)或工業(yè)裝置中固定敷設(shè)之用。

  The product is suitable for use in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 35KV.

  使用特性

  Operating characteristics

  1、 ● 額定電壓3.6/6KV~26/35KV交聯(lián)聚乙烯絕緣電力電纜

  XLPE Insulated Electrical Cable for rated power frequency voltage Uo/U:3.6/6KV~26/35KV.

  ● 電纜導(dǎo)體的允許長期高工作溫度為90℃。

  Max.permissible continuous operating temperature of conductor:90℃

  ● 短路時(長持續(xù)時間不超過5s)電纜導(dǎo)體的高溫度不超過250℃。

  Max.short-circuit temperature of conductor shall not exceed 250℃.(5s Max. Duration)

  ● 敷設(shè)電纜時環(huán)境溫度應(yīng)不低于0℃。

  The bending radius of single-core cable shall not less than 20 times of the cable diameter

  The bending radius of three-cores cable shall not less than 15 times of the cable diameter

  2、 ● 額定電壓0.6/1kv交聯(lián)聚乙烯絕緣電力電纜

  XLPE Insulated Electrical Cable for rated power frequency voltage Uo/U : 0.6/1KV

  ● 電纜導(dǎo)體的允許長期高工作溫度為90℃。

  Max.permissible continuous operating temperature of conductor : 90℃

  ● 短路時(長持續(xù)時間不超過5s)電纜導(dǎo)體的高溫度不超過250 ℃

  Max.short-circuit temperature of the conductor shall not exceed 250 ℃

  ● 敷設(shè)電纜時環(huán)境溫度應(yīng)不低于0 ℃

  The ambient temperature under installation shall not below 0 ℃

  ● 電纜彎曲半徑不小于電纜外徑15倍

  The bending radius of a cable shall not less than 15 times of the cable diameter .

  3、 ● 額定電壓0.6/1KV聚氯乙烯絕緣電力電纜。

  PVC Insulated Electrical Cable for rated power frequency voltage Uo/U : 0.6/1KV

  ● 電纜導(dǎo)體的允許長期高工作溫度為70 ℃

  Max.permissible continuous operating temperature of conductor : 70 ℃

  ● 短路時(長持續(xù)時間不超過5s)電纜導(dǎo)體高溫度不超過:160℃

  Max.short-circuit temperature of the conductor shall not exceed :160℃

  ● 敷設(shè)電纜時環(huán)境溫度應(yīng)不低于0 ℃

  The ambient temperature under installation shall not below 0 ℃

  ● 電纜彎曲半徑不小于電纜外徑10倍

  The bending radius of a cable shall not be less than 10 times of the cable diameter.

  電纜額定電壓的選擇

  Voltage designation

  ● 電纜的額定電壓應(yīng)適合于電纜使用系統(tǒng)的運行狀況,用Uo/U(Um)kv表示。

  Uo—電纜設(shè)計用的導(dǎo)體與屏蔽或金屬套之間的額定工頻電壓;

  U—電纜設(shè)計用的導(dǎo)體之間的額定工頻電壓;

  Um—設(shè)備可承受的“高系統(tǒng)電壓”的大值。

  The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used , and is expressed in the form Uo/U(Um)kv .

  Where:

  Uo—The rated power-frequency voltage between conductor and screen or metallic-sheath , for which the cable designed;

  U — The rated power –frequency voltage between conductors , for which the cable designed ;

  Um—The maximum value of the “highest system voltage “ for which the equipment may be operated.

  注:第一類——用于單相接地故障時間每一次一般不大于1min, 亦可用于長不超過8h , 第年累計不超過125h 的系統(tǒng)。

  第二類一一用于接地故障時間更長的系統(tǒng)及對電纜絕緣性能要求較高的場合。

  The first class cable-suitable for one single-phase earth-fault time does not exceed 1 min each time and Max.

  Time not exceed 8 hours , and not exceed 125 hours in all in one year.

  The second class cable suitable for more the earth-fault time and more better insulation performance

jenniferweiyi@outlook.com 售后服務(wù)
電話:0510-87904320
傳真:0510-87233666
客服時間:(9:00-18:00)